Skip to product information

Commercial Roof Exhaust Fan — Model Options

Commercial Roof Exhaust Fan — Model Options

Regular price $1,018.00
Regular price $1,018.00 Sale price $1,074.90
SAVE 5% Sold out
 
Technical support provider: Created with Sketch.
Commercial Roof Exhaust Fan — Model Options

Commercial Roof Exhaust Fan — Model Options

Regular price $1,018.00
Regular price $1,018.00 Sale price $1,074.90
SAVE 5% Sold out

Support a professionally engineered roof or canopy ventilation project with a commercial exhaust-fan format offered in several motor-rating options. This product is intended for planned installations where airflow, roof structure, weather protection, electrical supply, and service access are evaluated together.

The selector lists 0.25HP, 0.33 HP, 0.50HP, and 0.75HP configurations. Motor rating alone does not identify the complete performance envelope, so confirm the exact model, airflow data, dimensions, voltage, phase, controls, and application suitability before ordering.

Model choices for a designed exhaust system

  • Commercial roof-style exhaust format.
  • Aluminum-alloy housing described in the source information.
  • Four currently listed motor-rating choices.
  • Designed to be evaluated as part of a complete ventilation system.
  • Suitable for professional planning where roof curb, power, airflow, and weather details are known.

Choose the right option

Choose among 0.25HP, 0.33 HP, 0.50HP, and 0.75HP only from an engineered requirement. These values describe listed motor ratings, not color. No single airflow, voltage, sound level, or roof-opening dimension should be applied to all four options.

Product specifications

Product type Commercial roof exhaust fan
Housing material Aluminum alloy described in source
Listed motor options 0.25HP, 0.33 HP, 0.50HP, 0.75HP
Mounting format Roof or canopy-style exhaust
Airflow Model-specific; confirmation required
Electrical supply Model-specific; confirmation required
Phase and frequency Not confirmed here
Roof curb or opening Not confirmed; must match selected model
Controls Not confirmed
Certification and environmental rating Not confirmed

Engineering and roof coordination

Determine the required exhaust volume from the space use, heat, moisture, contaminants, hood or duct resistance, target pressure, and replacement-air strategy. Coordinate the selected fan with ductwork, dampers, curbs, roof structure, waterproofing, disconnects, and safe service access.

A qualified professional should confirm structural loads, wind and weather exposure, flashing, drainage, vibration isolation, electrical characteristics, motor protection, clearances, and applicable mechanical, fire, and electrical requirements. Do not select a motor rating without the matching fan curve and system data.

Project workflow

  1. Define the ventilation duty and obtain the required airflow and pressure values.
  2. Match a verified fan model and motor configuration to the system curve.
  3. Confirm roof curb, opening, structure, weatherproofing, and service clearances.
  4. Coordinate electrical supply, controls, disconnect, and protection.
  5. Commission the installed fan by checking rotation, airflow, vibration, current, and safe operation.

Care and safety

Commercial roof equipment can involve fall hazards, heavy components, rotating parts, weather exposure, and hazardous electrical energy. Installation, lifting, wiring, and service should be performed by appropriately qualified personnel using required safety controls.

Do not use the fan for explosive, flammable, grease-laden, corrosive, or otherwise hazardous exhaust unless the exact selected model is explicitly approved for that duty. This page does not claim a certification, hazardous-location rating, restaurant-hood approval, or weather class.

Before ordering

The listing provides motor-rating choices but not enough verified model data for final engineering. Confirm exact model number, airflow curve, static-pressure performance, voltage, phase, dimensions, curb compatibility, sound, weight, controls, certification, and included components before purchase.

Frequently asked questions

What do the options represent?

They represent listed motor ratings: 0.25HP, 0.33 HP, 0.50HP, and 0.75HP.

Is airflow the same for every option?

No. Airflow and pressure performance are model-specific and must be confirmed.

Does the fan include a roof curb?

A curb and other installation components are not confirmed as included. Verify the selected configuration.

Can this be used for restaurant grease exhaust?

That use is not claimed. It requires a specifically approved fan and code-compliant system.

What voltage does it use?

The exact voltage and phase are not confirmed on this page and must be checked for the selected model.

Is professional installation required?

Commercial roof mounting, lifting, weatherproofing, and electrical work should be handled by qualified professionals.

Need help confirming a detail? Email support@trieel.com with the product link and the option you are considering.

View full details